Click a tag to remove it from package
6 sampling points --> 3 in River Spree, 2 in Lake Müggelsee, 1 in River Erpe
2022: 4 occasional samples on 22.07., 11.08., 29.09., and 11.11.2022. Analyzed for trace organic contaminats, isotopes and anions (chloride, sulfate, nitrate)
2023: Biweekly grab samples from mid-March to mid-November. Analyzed for trace organic contaminants, isotopes, anions, and metals. Temporal high-resolution EC measurements (by CTD-Divers)
Details on files:
2022_2023_WTW_isotope_major ions_trocs --> data from 2022 and 2023 from grab samples including standard water parameters (with EC measurements), stable water isotopes, major ion concentrations, and TrOC concentrations
2022_2023_water balance_Lake Müggelsee --> water components for Lake Müggelsee water balance including inflow from River Spree, evaporation, precipitation, storage change, and daily mean air temperature
2020_2023_EC_HR EC --> Occasional EC measurements at Spree Tunnel and from present study from 2020 to 2023, daily mean EC from Lake Müggelsee (measured by Lake Müggelsee Monitoring station), Data from Figure 3a: HR EC from 2023 recorded by CTD-Divers, Precipitation data 2023 from East Berlin
chemistry:
0,45µm filtrated, inductively coupled plasma optical emission spectrometry (ICP-OES)
0,45µm filtrated, inductively coupled plasma optical emission spectrometry (ICP-OES)
since 2009 with ICP-OES
before 2009 with AAS
0,2µm filtrated, Ionenchromatographie (IC)
determination by conductivity-probe
0,45µm filtrated, photometric determination
0,45µm filtrated, inductively coupled plasma optical emission spectrometry (ICP-OES)
0,45µm filtrated, inductively coupled plasma optical emission spectrometry (ICP-OES)
0,45µm filtrated, inductively coupled plasma optical emission spectrometry (ICP-OES)
0,45µm filtrated, photometric determination
determination by oxygen-probe
pH-probe determination
determination with ICP/OES
0,45µm filtrated, inductively coupled plasma optical emission spectrometry (ICP-OES)
Si bis 06/2018 photometrisch
0,2µm filtrated, Ionenchromatographie (IC)
0,45µm filtrated, inductively coupled plasma optical emission spectrometry (ICP-OES)
Typically Deuterium / 2H and 18O.
0,45µm filtrated, inductively coupled plasma optical emission spectrometry (ICP-OES)
meteorology:
Title | created | Filetype | Actions |
---|---|---|---|
2020_2023_EC_HR_EC.xlsx | 01. Aug. 2024 10:48 | datatable: .xlsx |
Error:
To access file, please get in touch with the contact person.
|
2022_2023_water_balance_Lake_Müggelsee.xlsx | 01. Aug. 2024 10:47 | datatable: .xlsx |
Error:
To access file, please get in touch with the contact person.
|
2022_2023_WTW_isotope_major_ions_trocs.xlsx | 01. Aug. 2024 10:47 | datatable: .xlsx |
Error:
To access file, please get in touch with the contact person.
|
FRED provides all metadata of this package in a maschine readable format. There is a pure XML file and one EML file in Ecological Metadata Language. Both files are published under the freeODC-ByLicence.
You are about to leaving FRED and visting a third party website. We are not responsible for the content or availability of linked sites.
To remain on our site, click Cancel.
Estimated Time:
While parsing a file, the database has to perform various tasks, some of them needs a lot of CPU and memory for larger files.